CCQSP - MIL-E-15090C TYPE 2 CLASS 2, H8-014

  • MSDS: CCQSP
  • Manufacturer: CRAWFORD LABS INC
  • Product Name: MIL-E-15090C TYPE 2 CLASS 2, H8-014
  • National Stock Number: 8010-00-598-5934
Product Identification

Product ID:MIL-E-15090C TYPE 2 CLASS 2, H8-014
MSDS Date:11/21/1995
FSC:8010
NIIN:00-598-5934
MSDS Number: CCQSP

Responsible Party
CRAWFORD LABS INC
4165 SOUTH EMERALD AVE
CHICAGO, IL 60609
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 312-376-7132

Cage: LO674

Contractor
CRAWFORD LABS INC
CHICAGO, IL 60609 US

Telephone: 312-376-7132

Cage: LO674

Ingredients

1); (CALCIUM CARBONATE)

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: 20-50%

OSHA PEL N/K

ACGIH TLV: N/K


TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 1-5%

OSHA PEL 20 MPPCF

ACGIH TLV: 2 MG/M3 RDUST


DOLOMITE

Fraction By Weight: <5%

OSHA PEL N/K

ACGIH TLV: N/K


CHLORITE

Fraction By Weight: <5%

OSHA PEL 5 MG/M3 RESP DUST

ACGIH TLV: 10 MG/M3


SILICA, CRYSTALLINE - QUARTZ; (QUARTZ)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: <5%

OSHA PEL N/K

ACGIH TLV: 0.1 MG/M3 RDUST


CALCIUM CARBONATE; (CALCITE)

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: <5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


ACETIC ACID, BUTYL ESTER; (NORMAL BUTYL ACETATE) (CERCLA)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 5-20%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 200 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


W/SOAP & WATER. DO NOT REUSE CONTAMINATED CLOTHING

RTECS: 9999999ZZ


INCREASING VAP VOL & VAP/AIR CONTACT TIME &

RTECS: 9999999ZZ


TYPICAL ELEVATED TEMP PROCESS CONDITIONS, ESP IN

RTECS: 9999999ZZ


INGRESS OF AIR OR OUTSIDE PROCESS EQUIP OPERATING

RTECS: 9999999ZZ


TO THE ATMOSPHERE OCCURS. ANY PROPOSED USE OF THIS

RTECS: 9999999ZZ


EVALUATED TO ASSURE THAT SAFE OPERATING CONDITIONS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:OVEREXPOSURE MAY PRODUCE VARIOUS
EFFECTS INCLUDING: ACUTE TOXICITY RESULTING IN HEADACHE, DIZZINESS,
NAUSEA AND LOSS OF CONSCIOUSNESS. SEVERE EYE IRRITATION POSSIBLY
RESULTING IN PERMANENT DAMAGE. IRR ITATED MUCOUS MEMBRANES.
VOMITING DUE TO INGESTION. DEFATTING AND DRYING OF SKIN.
SENSITIZATION AFTER REPEATED CONTACT.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ: IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987;GROUP 2A. NTP 7TH ANNUAL
REPORT ON (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/PLENTY OF CLEAN LUKEWARM LOW PRESS WATER FOR AT
LEAST 15 MIN, OCCAS LIFTING EYELIDS OPEN. GET MED ATTN. INHAL:
REMOVE TO FRESH AIR & PROVIDE OXYGEN IF BRTHG IS DFCLT. GIVE ARTF
RESP IF N OT BRTHG. GET MED ATTN. KEEP VICTIM WARM & COMFORTABLE.
NEVER GIVE UNCON PERSON LIQS. INGEST: IF SWALLOWED, CALL MD IMMED.
ONLY INDUCE VOMIT ON INSTRUCTIONS OF MD. IF VOMIT OCCURS SPONT,
KEEP (SUPDAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:78.0F,25.6C
Lower Limits:3%
Extinguishing Media:FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER MAY BE USED TO KEEP EXPOS CNTNRS COOL & TO KEEP FLAM
STRUCTURES WET. DO NOT ENTER FIRE AREA W/OUT (SUPDAT)
Unusual Fire/Explosion Hazard:WATER PRESSURE MAY SPREAD A FLAMMABLE
LIQUID FIRE. SEALED CONTAINERS MAY EXPLODE IF OVERHEATED.

Accidental Release

Spill Release Procedures:WARNING - FLAMMABLE. ELIMINATE ALL IGNITION
SOURCES. HANDLING EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING.
SOAK UP WITH AN ABSORBENT AND PLACE IN NON-LEAKING CONTAINERS. SEAL
TIGHTLY FOR PROPER DIS POSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:TREAT AS A HAZARDOUS-FLAMMABLE
MATERIAL. KNOW APPLICABLE DOT REGULATIONS BEFORE ATTEMPTING TO
TRANSPORT THIS MATERIAL.
Other Precautions:"WARNING: HOT ORG CHEM VAPS OR MISTS ARE SUSCEPTIBLE
TO SUDDEN SPONT COMBUST WHEN MIXED W/AIR. IGNITION MAY OCCUR AT
TEMPS BELOW THOSE PUBLISHED IN LITERATURE AS "AUTOIGNITION" OR
"IGNITION" TEMPS. IG NITION TEMPS DECREASE WITH (ING 9)

Exposure Controls

Respiratory Protection:IMPORTANT - MUST PROVIDE ADEQUATE VENTILATION TO
MAINTAIN VAPOR CONCENTRATIONS BELOW THE ESTABLISHED TLV LIMIT AS
GIVEN BY OSHA. IN MORE CONFINED AREAS A NIOSH APPROVED RESPIRATOR
EQUIPPED WITH ORGANI C VAPOR CARTRIDGE SHOULD BE WORN.
Ventilation:MUST PROVIDE ADEQUATE VENTILATION.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: PROPER PROT BECAUSE HAZ DECOMP PRODS MAY BE PRESENT.
EXPLAN OF CARCIN: CARCINS, 1994:ANTIC TO BE CARCIN. FIRST AID PROC:
HEAD BELOW HIPS TO PVNT ASPIR OF LIQ INTO LUNGS. NEVER GIVE AN
YTHING BY MOUTH TO UNCON PERSON. SKIN: FLUSH W/WATER WHILE REMOVING
CONTAMD CLTHG & SHOES. FOLLOW BY WASHING (ING 8)

Chemical Properties

Boiling Pt:B.P. Text:>124F,>51C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.271
Evaporation Rate & Reference:3.41 X N-BUTYL ACETATE
Appearance and Odor:GREY LIQUID.
Percent Volatiles by Volume:12.9

Stability

Stability Indicator/Materials to Avoid:YES
MAY BE INCOMPATIBLE WITH OXIDIZING AGENTS AND STRONG ALKALIES.
Stability Condition to Avoid:AVOID HEAT, SPARKS, OPEN FLAMES AND
INCOMPATIBLES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION FOR PRODUCTS
LIKE THIS MAY GENERATE HIGHLY POISONOUS CARBON MONOXIDE AND OTHER
TOXIC GASES.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH CURRENT
LOCAL, STATE AND FEDERAL REGULATIONS. CONTACT AN APPROVED DISPOSAL
FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.